Products
| Features Compared |
Ergonom 1000 Series |
Ergonom 2000 Series |
Ergonom 3000 Series |
Ergonom 4000 Series |
||||||||
|
E1000-1 |
E1000-2 |
E1000-3 |
E2000-1 |
E2000-2 |
E2000-3 |
E3000-1 |
E3000-2 |
E3000-3 |
E4000-3 |
E4000-4 |
E4000-5 |
|
| Resolution Incident |
300nm |
300nm |
250nm |
250nm |
200nm |
200nm |
100nm |
100nm |
||||
| Resolution Transmitted |
300nm |
300nm |
250nm |
250nm |
200nm |
200nm |
100nm |
100nm |
||||
| True magnification limit |
Up to 2000x |
Up to 2500x |
Up to 4500x |
Greater than 8000x |
||||||||
| Numerical Aperture |
0.5 to 0.8 N.A. (dry) |
0.85 to 0.95 N.A. (dry) |
0.85 to 0.95 N.A. (dry) |
0.85 to 0.95 N.A. (dry) |
||||||||
| Color contrast |
Full, even at high magnifications |
Full, even at high magnifications |
Full, even at high magnifications |
Full, even at high magnifications |
||||||||
| White light source |
Even at high resolutions |
Even at high resolutions |
Even at high resolutions |
Even at high resolutions |
||||||||
| Variable DOF |
Even at high magnifications |
Even at high magnifications |
Even at high magnifications |
Even at high magnifications |
||||||||
| Contour sharpness |
Even at high magnifications |
Even at high magnifications |
Even at high magnifications |
Even at high magnifications |
||||||||
| Paralax free imaging |
At all resolutions |
At all resolutions |
At all resolutions |
At all resolutions |
||||||||
| Reflection free |
Yes |
Yes |
Yes |
Yes |
||||||||
| Staining (etc.) required |
Staining not necessary |
Staining not necessary |
Staining not necessary |
Staining not necessary |
||||||||
| Oil immersion required |
No, max. 0.8 N.A. |
No, max. 0.95 N.A. |
No, max. 0.95 N.A. |
No, 0.95 N.A./extended WD |
||||||||
| Brightfield |
Yes |
Yes |
Yes |
Yes |
||||||||
| Darkfield |
Yes, but Grayfield is better |
Yes, but Grayfield is better |
Yes, but Grayfield is better |
Yes, but Grayfield is better |
||||||||
| Grayfield |
Yes, with full color contrast |
Yes, with full color contrast |
Yes, with full color contrast |
Yes, with full color contrast |
||||||||
| Phase Contrast |
Yes, with contour sharpness |
Yes, with contour sharpness |
Yes, with contour sharpness |
Yes, with contour sharpness |
||||||||
| Living samples in vitro |
Yes, with Olbrich chambers |
Yes, with Olbrich chambers |
Yes, with Olbrich chambers |
Yes, with Olbrich chambers |
||||||||
| Sample warmth level |
Up to 3° C over room temp. |
Up to 3° C over room temp. |
Up to 3° C over room temp. |
Up to 3° C over room temp. |
||||||||
| Transparent samples |
Yes, incl. absolute transp. |
Yes, incl. absolute transp. |
Yes, incl. absolute transp. |
Yes, incl. absolute transp. |
||||||||
For each microscope, there are a wide range of dry objectives available to match your application, e.g. 2,5x, 4x, 10x, 20x, 40x, 60x, 80x, 100x with n.A. up to 0.95 - some with extended working distance (WD). As the costs of the individual objectives vary widely according to their specifications, general price quotes are not meaningful before your exact requirements have been determined.
Through the introduction of the entry level Ergonom 1000 and 2000 series, our microscopes have now become affordable to a much larger range of customers, while providing an image quality, depth of field and color contrast not attainable in most conventional microscope systems, especially for live cell analysis for example.
Sub-Menu: